Analytical-industries GPR-15 AXP Trace PPM Oxygen Analyzer Instrukcja Użytkownika Strona 1

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Ekwipunek Analytical-industries GPR-15 AXP Trace PPM Oxygen Analyzer. Analytical Industries GPR-15 AXP Trace PPM Oxygen Analyzer User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
Advanced Instruments Inc.
2855 Metropolitan Place, Pomona, CA 91767 USA Tel: 909-392-6900, Fax: 909-392-3665, e-mail: info@aii1.com, www.aii1.com
GPR-18MS / 18 / 28
ATEX Certified Explosion Proof
Oxygen Analyzer
Owner’s Manual
Przeglądanie stron 0
1 2 3 4 5 6 ... 38 39

Podsumowanie treści

Strona 1 - Advanced Instruments Inc

Advanced Instruments Inc. 2855 Metropolitan Place, Pomona, CA 91767 USA ♦ Tel: 909-392-6900, Fax: 909-392-3665, e-mail: [email protected], www.aii

Strona 2

Advanced Instruments Inc. 10 5 Operation Principle of Operation This ATEX Certified Explosion Proof Oxygen Analyzer is a precision device designe

Strona 3 - 1 Introduction

Advanced Instruments Inc. 11 Oxygen, the fuel for these electrochemical transducers, reacts chemically at the sensing electrode to produce an elect

Strona 4

Advanced Instruments Inc. 12 Electronics The signal generated by the sensor is processed by state of the art low design and

Strona 5

Advanced Instruments Inc. 13 GPR-18MS GPR-18 The advantages of the bypass sample system include: ¾ Supplying the

Strona 6

Advanced Instruments Inc. 14 Accuracy & Calibration Single Point Calibration: As previously described the galvanic oxygen sensor generates a

Strona 7

Advanced Instruments Inc. 15 Mounting the Analyzer The oxygen analyzer consists of two PCB assemblies, sensor housing and sample system valves. An

Strona 8

Advanced Instruments Inc. 16 Gas Connections The analyzers flow through configuration is designed for positive pressure samples and requires connec

Strona 9

Advanced Instruments Inc. 17 Procedure: 1. Disconnect the AC power source before servicing the analyzer. 2. Insert the power cable through t

Strona 10 - 5 Operation

Advanced Instruments Inc. 18 Alarms The analyzer is equipped with two user adjustable alarms located on the interior panel attached to the front d

Strona 11

Advanced Instruments Inc. 19 Installing the Oxygen Sensor Analyzers are equipped with an integral oxygen sensor that is tested and calibrated by t

Strona 12

Advanced Instruments Inc. 2 Table of Contents Introduction 1 Quality Control Certification 2 Safety 3 Features & Specifications 4 Operatio

Strona 13

Advanced Instruments Inc. 20 Establishing Power to the Electronics Establish power to the electronics by connecting the power cable to an appropria

Strona 14

Advanced Instruments Inc. 21 Procedure: 1. Open the front door to access the DISPLAY SELECT slide switch located on the A-1107 PCB Assembly Main/D

Strona 15

Advanced Instruments Inc. 22 Calibration The electrochemical oxygen sensors manufactured by Analytical Industries Inc. (dba Advanced Instruments) g

Strona 16

Advanced Instruments Inc. 23 Zero Calibration Offset Adjustment Capability: Designed to facilitate precise analysis below 5% of the most sensitive

Strona 17

Advanced Instruments Inc. 24 Span Gas Selection: The O2 concentration of a span gas should approximate 70-90% of the full scale range dictated by

Strona 18

Advanced Instruments Inc. 25 When installing a new oxygen sensor and calibrating with air: Allow 5-10 minutes for the sensor to equilibrate in ambi

Strona 19

Advanced Instruments Inc. 26 11. Caution: Turning the actuator/potentiometer more the ½ turn recommended does not allow the electronics sufficient

Strona 20

Advanced Instruments Inc. 27 Procedure: 1. Select the desired sampling range that provides maximum resolution. 2. Use metal tubing to transport t

Strona 21

Advanced Instruments Inc. 28 6 Maintenance With exception of components related to optional equipment and charging the battery of portable analyze

Strona 22

Advanced Instruments Inc. 29 7 Spare Parts Recommended spare parts for the GPR-18MS Explosion Proof ppm Oxygen Analyzer: Item No. Description G

Strona 23

Advanced Instruments Inc. 3 1 Introduction Your new ATEX Certified Explosion Proof Oxygen Analyzer is a precision device designed to give you yea

Strona 24

Advanced Instruments Inc. 30 Recommended spare parts for the GPR-18 Explosion Proof ppm Oxygen Analyzer: Item No. Description GPR-12-333 ppm Ox

Strona 25

Advanced Instruments Inc. 31 Recommended spare parts for the GPR-28 % O2 Analyzer include: Item No. Description GPR-11-32 Oxygen Sensor XLT-11-24

Strona 26

Advanced Instruments Inc. 32 8 Troubleshooting Symptom Possible Cause Recommended Action Slow recovery or response time At install

Strona 27

Advanced Instruments Inc. 33 Symptom Possible Cause Recommended Action Erratic O2 reading Change in sample pressure Dirt

Strona 28 - 6 Maintenance

Advanced Instruments Inc. 34

Strona 29 - 7 Spare Parts

Advanced Instruments Inc. 35

Strona 30

Advanced Instruments Inc. 36 9 Warranty The design and manufacture of Advanced Instruments Inc. oxygen analyzers and oxygen sensors are performe

Strona 31

Advanced Instruments Inc. 37 10 MSDS – Material Safety Data Sheet Product Identification Product Name Oxygen Sensor Series - PSR, GPR, AII, XLT

Strona 32 - 8 Troubleshooting

Advanced Instruments Inc. 38 Health Hazard Information Primary Route(s) of Entry Ingestion, eye and skin contact Exposure Limits Potassium Hydro

Strona 33

Advanced Instruments Inc. 39 Appendix A Electrical connections require an approved explosion proof sealing fitting and packing around wires and ca

Strona 34

Advanced Instruments Inc. 4 2 Quality Control Certification Date: Customer:

Strona 35

Advanced Instruments Inc. 5 3 General Safety & Installation Safety This section summarizes the basic precautions applicable to all analyzer

Strona 36 - 9 Warranty

Advanced Instruments Inc. 6 damage to the sensor or optional components. Consult the factory for recommendations concerning the proper selection an

Strona 37

Advanced Instruments Inc. 7 Application Pressure - Positive: A flow indicator with integral metering valve positioned upstream of the sensor is rec

Strona 38

Advanced Instruments Inc. 8 4 Features & Specifications

Strona 39 - Appendix A

Advanced Instruments Inc. 9

Komentarze do niniejszej Instrukcji